Outdoor & Security Lighting Real Power, Wet-Location Code, On at Dark
In mid-November in Pittsburgh it is dark before 5 PM, and the walk from the car to the door, the steps, and the back yard are outdoor-lighting problems for half the year. Good outdoor lighting is not a string of solar stakes — it is a power job first: GFCI-protected outdoor power, wet-location fixtures and covers, low-voltage runs sized and buried correctly, and controls that come on at dark without you thinking about them. This page is that job done plainly: security and motion lighting, landscape lighting, and patio and deck power — year-round lighting only — and what to send us so the quote is real.
Text photos of your yard, walkway, porch or deck — wide shots in daylight showing where light is needed, any existing outdoor outlets and fixtures, and your electrical panel (door open, breakers visible) — to (412) 326-9761 — the run's route, the existing outdoor power and the panel all show in photos, and that is the fastest way for us to tell you what the job actually involves.
Text photos to (412) 326-9761 Or send photos with the quote formFor jobs over $500, Pennsylvania law (HICPA) requires a signed written contract before any work begins or any payment is taken.
1. Outdoor lighting is a power job first
Every outdoor light is fed by something: a receptacle, a transformer, a switch leg, a run buried in the yard. When that power side is improvised — an indoor outlet with a cord through a window, a flat cover that floods, landscape cable an inch under the mulch — the lights are the least of the problem. The 2020 NEC JS Power scopes every quote to covers the outdoor side specifically, and the requirements below are the starting point of every quote we write for this work, not upgrades. Competitors across Pittsburgh run dedicated outdoor-lighting pages — Gillece publishes one, and North Hills shops list security and outdoor lighting by name — because homeowners search for it by name; this page is JS Power's version, in our own words and to our own standard.
- GFCI-protected outdoor power: outdoor receptacles need ground-fault protection under the 2020 NEC (210.8), a weather-resistant device, and an in-use cover that protects the connection while a cord is plugged in — not just when it is empty.
- Wet-location everything: fixtures, boxes, junctions and covers rated for the exposure they actually live in. Damp-location gear in a wet location is a scheduled failure, and it is the first thing an honest evaluation checks on existing installs.
- Low-voltage done as a system: landscape lighting under Article 411 runs from a listed transformer sized to the total load and the length of the run — undersized transformers and daisy-chained cable are why the far lights in a yard glow dimmer than the near ones.
- Controls that work at dark: photocells, timers or motion sensing specified for the job each light does — security lights that answer movement, path lights that are simply on when it is dark. No control brand or model is promised; the function is specified and verified working before we leave.
2. The electrical side most pages skip
- Existing outdoor power gets checked first: many North Hills homes have one outdoor receptacle, or none that still works. Its protection, condition and circuit are verified before anything new is hung on it — and adding a properly placed outdoor receptacle is often the real first job, quoted as such.
- Burial and routing in writing: cable and conduit type, burial depth and route for yard runs are specified in the written scope — a run under a walkway or across a garden bed is not the same job as a fixture beside the door, and the quote shows which one yours is.
- Switching from inside: outdoor lights you cannot switch from inside the house get forgotten, left on, or left off. Where the wiring allows, control goes where you actually live — by the door you use — and the scope says plainly when an older switch leg limits the options.
- No fixture brands or models promised: we install listed, wet-location fixtures suited to the scope. No specific fixture, transformer or control brand or model is sold or promised here — the electrical scope is what JS Power stands behind.
3. Three jobs that get called the same thing
- Security and entry lighting: motion-activated and dusk-to-dawn lighting at doors, garages, driveways and dark side yards — aimed so it lights the approach, not the neighbour's windows, on power that is GFCI-protected and weatherproof.
- Landscape and path lighting: low-voltage lighting for walkways, steps, trees and garden beds, planned from where people actually walk at night. Steps and grade changes get light first; decoration comes after footing is safe.
- Patio and deck power: properly placed outdoor receptacles, lighting and switching for the spaces people sit in — quoted with the receptacle and protection work included, not as a cord run from inside the house.
4. Honest limits — and what this page is not
- Electrical only: JS Power does the wiring — circuits, receptacles, protection, transformers, fixtures and controls. We do not do landscaping, hardscaping, planting or masonry, and the quote does not pretend otherwise; your landscaper handles their side, we handle the power.
- Year-round lighting only: this page covers permanent, year-round outdoor lighting and power. It is not seasonal or holiday display installation, and nothing here is quoted as one.
- Existing installs get an honest read: a yard full of dead low-voltage lights is usually a transformer, cable or connection failure, not a full replacement. That starts as troubleshooting — findings in writing: what failed, what is still sound, and what fixing it actually takes.
5. What to send us for a real quote
- Wide daylight photos of each area that needs light — walkway, steps, driveway, deck or yard — showing the whole run, not just the fixture spot.
- Photos of every existing outdoor receptacle and fixture, close enough to show covers and condition — existing power is the first question.
- A photo of your electrical panel, door open, breakers and label visible, if a new circuit or receptacle is part of the job.
- One line on what bothers you: the dark steps, the unlit driveway, the dead landscape lights — the problem ranks the scope better than a fixture list does.
Text those to (412) 326-9761. The scope and the quote come back in writing, to the 2020 NEC — and like every JS Power quote, the work itself is only sent once it has been fully checked.
What it costs (honestly)
Troubleshooting and service calls are $75/hr + $50 trip — that is the only rate we publish. Anything bigger is scoped to the 2020 NEC and quoted in writing from photos before work starts. For jobs over $500, Pennsylvania law (HICPA) requires a signed written contract, and every quote here is good for 7 days.
Text photos of your yard and existing outdoor outlets to (412) 326-9761.
Common questions
Do outdoor outlets need GFCI protection?
Yes. Outdoor receptacles at a house need ground-fault protection under the 2020 NEC (210.8), plus a weather-resistant receptacle and an in-use cover that keeps water out while a cord is plugged in. An old outdoor outlet with a flat flip cover and no GFCI protection is the most common failure we find on this work — it is corrected as part of the scope, not left behind new lighting.
Is low-voltage landscape lighting safer to install?
Low-voltage landscape lighting (2020 NEC Article 411) runs at 30 volts or less from a listed transformer, so the yard wiring itself is lower risk — but the transformer still plugs into a 120-volt GFCI-protected outdoor receptacle, its location and load still matter, and the cable still has to be buried and routed correctly for the fixtures it feeds. Cheap kits fail at the transformer, the connections and the cable, not the lamps. We scope the power side properly and size the transformer to the run.
Why do my outdoor lights keep tripping the GFCI or breaker?
Water is the usual cause: a flooded fixture, a cracked in-use cover, a nicked cable, or a junction that was never weatherproof. A GFCI that trips outdoors is detecting exactly the fault it exists for — do not move the lights to an unprotected outlet to stop the tripping. Troubleshooting is $75/hr + $50 trip; the fault is found and identified in writing first, then the repair is scoped to the 2020 NEC.